F6-424 TOS6 - Hibarnation interrupted by logrotate

Discuss, seek assistance, and report issues related to hardware components, such as hardware platforms, memory, network ports, power supplies, UPS systems, and so on.
Post Reply
User avatar
jollino
Posts: 53
Joined: 24 Jul 2024, 02:33
Italy

F6-424 TOS6 - Hibarnation interrupted by logrotate

Post by jollino »

Hello,
I have a F6-424 on TOS6 (can't upgrade to TOS7 at this time), with six Ironwolf disks set to hibernate.
This works for the most part, especially if I set it to 10 minutes of inactivity, but ideally I'd like to keep it to 1 hour.

The problem is that logrotate accesses the disks every hour, and wakes the disks up. With a one-hour timeout, this ultimately means that the disks never get to hibernate.

Oct 16 15:00:07 Supernova systemd[1]: Condition check resulted in Kernel Security Modules - SMACK being skipped.
Oct 16 15:00:07 Supernova systemd[1]: Condition check resulted in Security Spcack being skipped.
Oct 16 15:00:07 Supernova systemd[1]: Starting Rotate log files...
Oct 16 15:00:07 Supernova systemd[1]: logrotate.service: Deactivated successfully.
Oct 16 15:00:07 Supernova systemd[1]: Finished Rotate log files.
[…]
Oct 16 16:00:07 Supernova systemd[1]: Condition check resulted in Kernel Security Modules - SMACK being skipped.
Oct 16 16:00:07 Supernova systemd[1]: Condition check resulted in Security Spcack being skipped.
Oct 16 16:00:07 Supernova systemd[1]: Starting Rotate log files...
Oct 16 16:00:07 Supernova systemd[1]: logrotate.service: Deactivated successfully.
Oct 16 16:00:07 Supernova systemd[1]: Finished Rotate log files.

I found a systemd timer for it:

master@Supernova:/var/log# systemctl list-timers --all | grep logr
Fri 2026-10-16 17:00:00 CEST 51min left Fri 2026-10-16 16:00:07 CEST 8min ago logrotate.timer logrotate.service

But I'm wondering if I should edit /etc/systemd/system/timers.target.wants/logrotate.timer directly (e.g. changing OnCalendar=hourly to OnCalendar=daily), or there's some "more official way" of doing that from the web interface that I may have missed.

Thanks!
User avatar
CursaYang
TM Support
Posts: 995
Joined: 06 Jan 2025, 16:34
China

Re: F6-424 TOS6 - Hibarnation interrupted by logrotate

Post by CursaYang »

We have noticed this issue and plan to address it in TOS 7.

May I ask what exactly prevents you from upgrading to TOS 7?
To contact our team, please send email to following addresses, remember to replace (at) with @

Technical team: support(at)terra-master.com(for technical support)
Service team: service(at)terra-master.com(for purchasing, return, replacement, RMA service)
User avatar
jollino
Posts: 53
Joined: 24 Jul 2024, 02:33
Italy

Re: F6-424 TOS6 - Hibarnation interrupted by logrotate

Post by jollino »

Thanks, I will start by changing the timer to daily; slightly bigger logs aren't going to be an issue. :-)

I'm hesitant to upgrade because my NAS is currently working reliably, and I had a rather unpleasant experience during the TRAID-to-TRAID+ migration: the web interface/backend got stuck and TerraMaster support had to intervene remotely to change a flag before the new configuration was recognized correctly. I can't recall the details as it's been a while, but it took a considerable amount of time, both before and during the remote appointment via TeamViewer.

I'd rather not risk disrupting a working RAID6 setup just to work around a bug in the current OS, especially since any issues over 30 TB of data would be quite inconvenient. Besides, from the marketing materials I don't see any specific features in TOS 7 that I miss in TOS 6 (in fact, to be honest I'm not entirely fond of the shift towards "AI", at least for my own use case). Actually, the only two issues I found with TOS 6 are this one, which I only just noticed as I previously kept my disks spinning at all times, and the fact that docker containers aren't started automatically on the rare occasion the NAS needs to be rebooted.

I will keep an eye on TOS 7 releases, hoping that the upgrade path is more and more stable (I have read a few sparse but terrifying horror stories...!), and pull the trigger when I'm confident I can deal with any potential issues that may crop up.
User avatar
EriChan
TM Support
Posts: 425
Joined: 06 Jan 2026, 12:27
China

Re: F6-424 TOS6 - Hibarnation interrupted by logrotate

Post by EriChan »

jollino wrote: ↑18 Oct 2026, 04:42
Thank you very much for your candid feedback regarding past migration experiences, upgrade hesitations, and feature preferences. As long as TOS 6 continues to reliably meet your daily needs, please feel free to stay on it and use it with peace of mind.

If you ever decide to upgrade to TOS 7 in the future and have any questions, please feel free to reach out to us anytime!
To contact our team, please send email to following addresses, remember to replace (at) with @

Technical team: support(at)terra-master.com(for technical support)
Service team: service(at)terra-master.com(for purchasing, return, replacement, RMA service)
Post Reply

Return to “Hardware, Power and Accessories”